DZH Manual Jute Waste Fabric Biomass Steam Boiler
DZH series steam boiler, also called jute waste fabric steam boiler, which needs labour to feed fuel and remove the dregs.
Introduction
DZH series steam boiler, also called jute waste fabric steam boiler, which needs labour to feed fuel and remove the dregs.
It has fire tube and water tube structure, suitable for small capacity less than 6tons/h. The fuels can be coal, wood log, wood chip, wood waste, jute,waste fabric,rice husk and other solid fuel, ect.
Features:
1. It's a adaptable to a wide range of fuels including jute,waste fabric,bituminous coal, lean coal and anthracite;
2. Thermal efficiency 5%-15% higher than other boilers, annual cost savings for 10tph boiler as high as USD70000;
3. Saving money and time: custom designed and feeding system, slag discharge system, flue gas treatment system;
4. Easy feeding and discharge, high level of automation that requires less operational and maintenance personnel;
5. Safety assured by the advanced interlock control system.
Biomass Steam Boiler Working Video:
It has fire tube and water tube structure, suitable for small capacity less than 6tons/h. The fuels can be coal, wood log, wood chip, wood waste, jute,waste fabric,rice husk and other solid fuel, ect.
Features:
1. It's a adaptable to a wide range of fuels including jute,waste fabric,bituminous coal, lean coal and anthracite;
2. Thermal efficiency 5%-15% higher than other boilers, annual cost savings for 10tph boiler as high as USD70000;
3. Saving money and time: custom designed and feeding system, slag discharge system, flue gas treatment system;
4. Easy feeding and discharge, high level of automation that requires less operational and maintenance personnel;
5. Safety assured by the advanced interlock control system.
Biomass Steam Boiler Working Video:
Technical Parameter
Model | DZH1-1.0-SCI | DZH2-1.0-SCI DZH2-1.25-SCI DZH2-1.6-SCI |
DZH4-1.25-SCI DZH4-1.6-SCI |
DZH6-1.25-SCI DZH6-1.6-SCI DZH6-2.5-SCI |
SZH10-1.25-SCI SZH10-1.6-SCI SZH10-2.5-SCI |
SZH15-1.25- SCI SZH15-1.6- SCI SZH15-2.5- SCI |
SZH20-1.25-SCI SZH20-1.6-SCI SZH20-2.5-SCI |
Rated Steam Capacity(t/h) | 1 | 2 | 4 | 6 | 10 | 15 | 20 |
Rated Working Pressure(Map) | 1.0 | 1.0/1.25/1.6 | 1.25/1.6 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 |
Rated Steam Temp.(℃) | 184 | 184/194/204 | 194/204 | 194/204/226 | 194/204/226 | 194/204/226 | 194/204/226 |
Feed-water Temp.(℃) | 20 | 20 | 20 | 60 | 60 | 60 | 104 |
Boiler proper heating area(m2) | 33.5 | 63.5 | 116 | 156 | 235.6 | 412 | 508 |
Effective Boiler Area(m2) | 2.1 | 3.2 | 5.2 | 7.8 | 11.8 | 17.3 | 21 |
Water Volume(m3) | 3.6 | 6.5 | 9.2 | 7.3 | 12.4 | 15.3 | 21.6 |
Design Efficiency (%) | >82 | >82 | >82 | >82 | >82 | >82 | >82 |
Design of Fuel | Biomass, Jute, Waste Fabric Fired | ||||||
Fuel Consumption (kg/h) | 175 | 350 | 700 | 1048 | 1748 | 2620 | 3496 |
Transportation size(L*W*H)(m) | 4.7*1.8*2.9 | 5.0*2.6*3.4 | 6.0*2.9*3.6 | 5.3*3.1*3.5 | 6.8*3.4*3.5 | 8.8*3.4*3.54 | 10.2*3.41*3.54 |
Weight(t) | 13 | 17 | 28 | 25 | 31 | 42 | 50 |
Request a Quote